COMPANY-----------MicroFIT & FIT------------CONTACT US
GO GREENER!
GO GREENER!

Renewable Energy
Systems & Componets

COMPLETE SYSTEMS

SOLAR PANELS

INVERTERS

TRACKERS & MOUNTING SYSTEMS

BATTERIES

CABLES
& WIRING

ELECTRICAL ENCLOSURES & SAFTEY

CHARGE
CONTROLERS
METERS, COMM.S & SITE ANALYSIS
DC TO DC VOLTAGE CONVERTER INVERTER POWER PANELS
 

SOLAR WATER PUMP

 


Need Help Selecting Components?

Contact Us


PRODUCTS
Batteries
Batteries: Flooded Lead Acid
Batteries: Sealed Agm
Batteries: Sealed Gel Cell
Desulfators
Enclosures
Ventilators/Battery Fans
Watering Caps

Books, Classes & Educational Videos

Classes
Educational Videos
General Renewable
Micro Hydropower
Solar Electric and Passive Solar
Solar Hot Water Systems
Wind Energy

Cables & Wiring

Battery Interconnects
Battery To Inverter
Tools
Wire By The Foot
Wiring For Solar Panels

Charge Controllers

Solar Charge Controllers
Solar Lighting Controllers
AC Charge Controllers
Constant Voltage Regulator
Diversion Load Controllers
Temperature Sensors

Composting

BigBelly Compactor
Compost Toilets
Garden Composters

DC Voltage Converters

Enclosures, Electrical and Safety

Electrical Enclosures
Lightning Protection
Miscellaneous Electrical Parts
NEC Compliant Safety Labels
Outback Flexware Components
Overcurrent Devices (Fuses & Breakers)
Switch Gear Disconnects

How To Section
Inverters
Export Inverters (230V 50Hz)
Inverter Accessories
Marine Inverters
Mobile / RV Inverters
Off-Grid: (No Utility-Needs Batteries)
On-Grid & Off-Grid Capable Inverters
On-Grid: (Grid Intertie-No Batteries)

Kits and Package Deals

Grid-Tied Systems
Grid-Tied with Battery Backup
Off-Grid Cabin Systems
Off-Grid Residential Systems
Other Packages and Special Deals
RV Solar Packages

Meters, Communications
& Site Analysis

Data Communications
Meters & Battery Monitors
Shunts
Solar Site Analysis Tools
System Monitors
Wind Data Instruments

Portable Power

Solar Panel Mounts & Trackers

Active Trackers
Ground Mounts
Passive Trackers
Roof Mounts
RV & Specialty
Side Of Pole
Top Of Pole

Solar Panels

1 to 50 Watt Solar Panels
51 to 99 Watt Solar Panels
100 to 149 Watts Solar Panels
150 Watts & Up Solar Panels
Flexible / Rollable Solar Panels
Foldable Solar Panels
Solar Panels by the Pallet
BIPV - Building Intergrated Photovoltaics
Solar Electricity Education

Wind Turbines

VAWT Wind Turbines (Electric)
HAWT Wind Turbines (Electric)
Wind Turbine Towers
Wind Data Instruments
Wind Power Education

RENEWABLE ENERGY SYSTEMS & COMPONENTS

Batteries - Measuring State of Charge

Voltage and State-of-Charge - a Cautionary Note

Please note that voltage is not the most accurate measure of state-of-charge. Voltage readings fluctuate based on various prevailing conditions at the time of measurement. Use change of voltage as an indicator of changing conditions or relative state-of-charge under similar conditions over time. For more accurate state-of-charge readings, a shunt based monitoring system is recommended.

Flooded Lead-Acid Batteries

Measuring the specific gravity (SG) of the battery electrolyte can provide the best measure of the flooded lead-acid battery’s state of charge (SOC). Measuring voltage is one way to estimate the state of charge of a battery; however voltage readings may vary depending upon whether the battery is being charged, discharged or is at rest (open cell). Whether the battery is under load at the time of the reading has little effect on the specific gravity of a tested cell. Additionally, specific gravity is good for measuring overall battery bank health. By measuring the SG of each cell, you can catch cell-to-cell or battery to battery differences that can result in untimely battery death.

Trojan Battery tips for Specific Gravity Testing (Flooded batteries only)
Source: Trojan Battery

1. Do not add water prior to testing.
2. Fill and drain the hydrometer 2-4 times before drawing a sample from the battery.
3. Have enough sample electrolyte in the hydrometer to completely support the float.
4. Take a reading, record it and return the electrolyte to the cell.
5. Check all cells in the battery, repeating the steps above.
6. Replace vent caps and wipe off any electrolyte that might have been spilled.
7. Correct the readings to 80°F:
Add 0.004 to readings for every 10° above 80°F.
Subtract 0.004 for every 10° below 80°F.
8. Check the state of charge using the table provided by the manufacturer.
The readings should be within the factory specification of 1.277 +/- 0.007.

Examples of SG Readings as compared with SOC (Source: Rolls Battery)

% Charged

Specific Gravity

100%

1.255 - 1.275

75%

1.215 - 1.235

50%

1.180 - 1.200

25%

1.155 - 1.165

0%

1.110-1.130

Sealed Batteries

The state-of-charge of sealed batteries cannot be determined by looking at the specific gravity of the electrolyte, since the batteries are, well, sealed! SOC can be determined by measuring the voltage; this is most accurate when the battery has been removed from a load for at least 6 hours, preferably 24 hours. Otherwise voltage values can fluctuate based on whether the battery is being charged or discharged. Here is a chart from MK Battery showing different levels of charge for flooded lead-acid and sealed batteries – open circuit voltage.

Comparison of Battery State-of-Chart to Open Circuit Voltage for 12-Volt Batteries

% Charge

FLA

Gel

AGM

100

12.70-12.60

12.95-12.85

12.90-12.80

75

12.40

12.65

12.60

50

12.20

12.35

12.30

25

12.00

12.00

12.00

0

11.80

11.80

11.80

Note: Divide values in half for 6-Volt batteries.

The time it takes to fully recharge a battery depends upon:

  • Depth of discharge

  • Temperature

  • Size and efficiency of charger

  • Age and condition of battery

 

References:
Rolls Battery
Trojan Battery
Home Power #9 February/ March 1989